Description
The Goodman DSZC160481 is a condenser with both heating and cooling capabilities for a split system installation. This outdoor component needs to be connected with an indoor air handler or evaporator coil to create a complete air conditioning system. This allows for many options for personalizing an HVAC system, which can be altered depending on desired energy-efficiency, cost, installation type and number of cooling and heating zones.
This two-stage model with heat pump is capable of an impressive 16 SEER efficiency when paired with the correct components. Specific ratings will depend in the indoor air handler or furnace used. This Goodman condenser features a 4 ton heating and cooling capacity at 48,000 BTU. It's usually recommended that the tonnage of the outdoor condenser be less than the indoor unit.
The DSZC16 line of split system air conditioners uses a two-stage, high-efficiency Copeland UltraTech scroll compressor. Cooling is created with the environmentally friendly R-410A chlorine-free refrigerant. The ComfortNet Communications System can be used with this model, providing convenient digital communication between Goodman HVAC systems and indoor control panels. This Goodman condenser is reliably constructed and protected by a heavy-gauge galvanized-steel cabinet with a baked on powder paint finish. Goodman has also packaged this heat pump to have the following factory-installed components:
- Bi-flow liquid-line filter drier
- Suction-line accumulator
- Compressor crankcase heater
- High-capacity muffler
- Coil and ambient temperature sensors
Features
- Two-Stage Copeland® UltraTech scroll compressor
- R-410A environmentally friendly refrigerant
- Copeland® ComfortAlert diagnostics
- ComfortNet™ Communications System compatible
- Two-Speed condenser fan motor
- High-quality foam compressor sound blanket
- Loss of charge switch
- High-pressure switch
- Factory-installed filter dryer
- Copper tubing / enhanced aluminum fin coil
- Sweat connection service valves with easy access to gauge ports
- ARI Certified; ETL Listed
- Wire fan discharge grille
- Steel louver coil guard
- Baked-on powder paint finish
- Rust-resistant coated screws
- Compact footprint
- Top and side maintenance access
- Single-panel access to controls with space provided for field-installed accessories
- When central air conditioner is properly anchored, meets the 2001 Florida Building Code unit integrity requirements for hurricane-type winds
Description
The Goodman AVPTC48D14 is a multi-position, variable-speed air handler with internal factory-installed thermal expansion valves. It is compatible with ComfortNet communication systems for convenient control over this unit. It has a top-of-the-line, all-aluminum evaporator coil. This model can be installed in horizontal or vertical configurations, providing many heating and cooling options for the customer.
This Goodman air conditioner comes from the AVPTC line of air handlers. It features a blower cooling capacity of 4 tons with a nominal cooling rating of 48,000 BTU/h. For effective cooling, this air handler uses a variable-speed ECM blower motor.
This multi-position air handler comes with many impressive features that make it a great choice for your home. Its cabinet is made with a rigid SmartFrame design for durability and it has a galvanized, leather grain-embossed finish. A CFM indicator and six-recent fault recall make it easy to monitor performance. The design of this model reduces condensation through screwless sides and back and a foil-faced insulation covering the internal casing. Plus, this Goodman air handler is easy to maintain with tool-less access to the filter.
Specification
Configuration |
Downflow / Horizontal / Upflow |
Blower Cooling Capacity |
4 Tons |
CFM (Low/High) |
(1350/1800) CFM |
Electric Heat Capabilities (Optional) |
10 / 15 / 20 / 5 / 6 / 8 Kilowatts |
Refrigerant |
R-410A |
Blower Type |
Variable Speed |
Maximum Overcurrent Protection (Breaker) |
15 Amps |
Fuel Type |
Electricity |
Requires Downflow Kit |
Yes |
Liquid Line Connection Size |
3/8 Inches |
Suction Line Connection Size |
7/8 Inches |
Supply Air Opening Size |
23.3125 x 11.3 Inches |
Return Air Opening Size |
21.1875 x 19.5 inches |
Shipping Weight |
167 lbs |
Width |
24 1/2 Inches |
Depth |
21 Inches |
Height |
58 Inches |
Voltage |
208 / 230 / 240 Volts |
Frequency |
60 Hz |
Voltage Phase |
1 |
Parts Warranty |
10 Years |
Description
The Goodman HKSX08XC is an electric heat kit. It comes from the HKS line, which is intended for use with Goodman air handlers. This model uses rust-resistant nickel chromium heating elements and has 8 kW nominal heating.
This Goodman heat kit features sequences for better temperature control. It has multiple branch circuit capability and has been completely assembled and tested so our customers know they are good to go. Plus, Goodman electronic heat kits are known for being easy to install and a plug-in wiring harness makes it simple to fit into the air handler.
Features
- Sequencers for better temperature control
- Multiple branch circuit capability
- Completely assembled and tested
- Control circuitry arranged to readily permit staging
- Factory-installed circuit breakers available on specific models
- Fuse link secondary high-temperature limit control
- Plug-in wiring harness for ease of installation into air handler
- Rust-resistant nickel chromium heat elements
- ETL Listed
Specification
- Wt. Lbs.: 8
- Breaker No
- Nom. kW 8.0
- Shipping Weight 3.45
- Shipping Width 10.00
- Shipping Length 15.04
- Shipping Height 8.43
Description
A specially formulated super-hydrophobic (water repelling) product in a convenient aerosol package for field service. The non-conductive formula has numerous applications in the management of water on non-food, non-potable water surfaces for the HVAC/R trade; surfaces that are not exposed to ongoing abrasion (hand and foot traffic).
-
Slows ice formation on refrigeration coils/cold plates
-
Provides added corrosion resistance to coils
-
Improves corrosion resistance to system components. Examples include circuit boards, filter-driers, flow control valves, equipment covering, etc.
-
Provides added corrosion protection of solder connections on low voltage circuit boards
-
Self-cleaning properties reduce rate of grime on outdoor coils
-
Reduces rate of bacterial growth on non-food, non-potable water surfaces
-
Improves water dispersion in condensate pans
-
Many other applications!
Specification
Cooling Capacity |
48000 BTU |
Cooling Capacity |
4 Tons |
Maximum Heating Output BTU |
48000 BTU |
SEER |
16 SEER |
Heating Seasonal Performance Factor |
9.75 HSPF |
Refrigerant |
R-410A |
Maximum Overcurrent Protection (Breaker) |
45 Amps |
Compressor Type |
Scroll UltraTech™ |
Low Pressure Safety Switch |
Yes |
Liquid Line Connection Size |
3/8 Inches |
Suction Line Connection Size |
7/8 Inches |
TXV Required |
Yes |
Noise Level |
74 Decibels |
Pad Size |
36x36 Inches |
Shipping Weight |
282 lbs |
Width |
35 1/2 Inches |
Depth |
35 1/2 Inches |
Height |
38 1/4 Inches |
Voltage |
208 / 230 Volts |
Frequency |
60 Hz |
Voltage Phase |
1 |
Compressor Warranty |
Lifetime With Online Registration |
Parts Warranty |
10 Years |
Directions
This product must be used in accordance to the following directions by HVACR professionals only.
- Disconnect all power to the equipment before use. Do not spray near sparks, heat or open flame. Discontinue the use of power tools during use. Do not smoke while applying product.
- Shake well before use. Use outdoors or in a well-ventilated area. Keep area ventilated until fumes are gone. Avoid breathing of fumes during application.
- Ensure surface is clean and mostly to fully dry before applying. After a coil cleaning, the surface needs to be blown dry with an inert gas to remove excess moisture from the surface before applying Nu-Shield.
- From a distance of 6-12 inches, spray a light coat on the surface, but no more beyond it being visibly wet. In other words, ‘Wet It and Forget It’. Contents in the canister will cover approximately 100 square feet. Depending on ambient conditions, allow a minimum of 20 minutes for Nu-Shield to dry on surface. Ensure surface appears visually dry and fumes are gone from the area before turning on power to equipment.
Note: Product needs to be applied after each coil cleaning. For best results, especially in corrosive environments, the product should be reapplied annually.